LS Series

LS Series

Precision High Voltage Modules

LS001, LS2.5, LS005, LS010, LS015, LS020, LS030, LS050

Applications: Mass spectrometers, Electron microscopes, Nuclear instruments, Photomultiplier tubes, Microchannel plates

  • 1kV, 2.5kV, 5kV, 10kV, 15kV, 20kV, 30kV, 50kV
  • Highest Stability, Lowest Ripple, Lowest Drift
  • Externally programmable or Internal control (opt)
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field
  • Positive, negative & remote reversible versions

The LS Series sets a new standard for high voltage precision and stability. By optimizing the Low Stress™ technologies used in our leading 10 Watt HP Series for 1 Watt applications, the new LS Series has less than 1ppm ripple, 10ppm/°C temperature coefficient, and 50ppm drift/hr throughout the range. Each of the units includes a differential control input.

All units are short circuit proof and use proven techniques to drive a high frequency oscillator and ferrite high voltage step-up transformer. These advanced power supplies build on Applied Kilovolts' legendary reputation for reliability, being constructed from conservatively rated components with their reliability further enhanced by information gained over many years of field operation.

Available as positive and negative units up to 50kV, and electrically reversible at voltages up to 30kV. Please see the HPZ range for zero crossing reversible (bi-polar) units.

We manufacture a large number of customized OEM versions and would be pleased to discuss your application with you.

Electrical Specification Positive & Negative Polarity Units
Unipolar Unit Type Output Voltage Output Current Ripple At Full Load Temp-Co (°C) &Size (mm) Weight
LS001xIP010 10V to 1kV 1mA <2mV (pk-pk) <10ppm 152 x 124 x 63 1.2
LS2.5xIP010 10V to 2.5kV 400uA <3mV (pk-pk) <10ppm 152 x 124 x 63 1.2
LS005xIP010 10V to 5kV 200uA <5mV (pk-pk) <10ppm 152 x 124 x 63 1.2
LS010xIP010 20V to 10kV 100uA <10mV (pk-pk) <10ppm 152 x 124 x 63 3
LS015xIP010 30V to 15kV 66.7uA <15mV (pk-pk) <10ppm 207 x 148 x 74 4
LS020xIP010 50V to 20kV 50uA <20mV (pk-pk) <10ppm 207 x 148 x 74 4
LS030xIP010 100V to 30kV 33.3uA <30mV (pk-pk) <10ppm 207 x 148 x 74 4
LS050xIP010 200V to 50kV 20uA <50mV (pk-pk) <10ppm 333 x 204 x 119 12.5
Electrical Specification REVERSIBLE POLARITY UNITS
Reversible Unit Type Output Voltage Output Current Ripple At Full Load Temp-Co (°C) Size (mm) Weight (kg)
LS001RIP010 ±10V to ±1kV 1mA <2mV (pk-pk) <10ppm 162 x 152 x 71.5 1.7
LS2.5RIP010 ±10V to ±2.5kV 400uA <3mV (pk-pk) <10ppm 162 x 152 x 71.5 1.7
LS005RIP010 ±10V to ±5kV 200uA <5mV (pk-pk) <10ppm 162 x 152 x 71.5 1.7
LS010RIP010 ±20V to ±10kV 100uA <10mV (pk-pk) <10ppm 162 x 152 x 71.5 1.7
LS015RIP010 ±30V to ±15kV 66.7uA <15mV (pk-pk) <10ppm 233 x 204 x 114 10
LS020RIP010 ±50V to ±20kV 50uA <20mV (pk-pk) <10ppm 233 x 204 x 114 10
LS030RIP010 ±100V to ±30kV 33.3uA <30mV (pk-pk) <10ppm 333 x 204 x 119 12.5
Input Voltage +24 volt d.c. ±10% at <150mA, for Unipolar, and at <200mA for Reversibles. Negative input terminal common to HV earth return.
Output Voltage See tables above.
Line Regulation Less than 2ppm of maximum voltage for input changes of 1 volt.
Load Regulation Less than 2ppm for load changes from (Measured at maximum voltage).
Overload Protection Flashover and short circuit proof. Re-entrant current limit.
Temperature Co-Efficient <10ppm/°C from 20°C to 50°C
Drift <50ppm per hour (<0.005%)
<100ppm per 8 hours (<0.01%)
Measured at constant input voltage, load current & ambient temperature after 0.5 hour warm up.
Control 10V analogue signal. (0 to Input impedance > 100Kohm.
EXTERNAL potentiometer = Option Code PP
INTERNAL potentiometer = Option Code FP
Readout Voltage monitor : 0 to +10V represents zero to maximum output, tolerance ±2% (Source resistance 10k).
Precision Current Monitor : 0 to 10V represents zero to of FS.
Operating Temperature 0°C to +50°C
Storage Temperature -35°C to +85°C
R.F.I. Steel case for low radiated magnetic field.
Mechanical Specification
Fixings Blind Fasteners front and rear.
Output By 1 meter screened cable, or optional integrated high voltage connector N.B. Reducing the cable length may increase the ripple voltage.
Input Connector 15 way D-type