PLEASE BE ADVISED THAT WE ARE CURRENTLY EXPERIENCING ISSUES WITH OUR INCOMING TELEPHONE SYSTEM.
IF YOU ARE UNABLE TO REACH US BY TELEPHONE, PLEASE USE THE EMAIL ADDRESSES ON THE CONTACT PAGE OR FILL IN THE CONTACT FORM AND ONE OF OUR TEAM MEMBERS WILL GET BACK TO YOU.
Applications: Mass spectrometers, Electron microscopes, Nuclear instruments, Photomultiplier tubes, Microchannel plates
The LT Series builds on the new standard for high voltage precision and stability set by the LS 1W family. By optimising the Low Stress™ technologies pioneered in the LS family, the LT Series provides 3W o/p capability, but still has less than 2ppm ripple, 10ppm/°C temperature coefficient, and 75ppm drift/hr throughout the range, while retaining the same LS case dimensions.
Each of the units includes a differential control input.
All units are short circuit proof and use proven techniques to drive a high frequency oscillator and ferrite high voltage step-up transformer. These advanced power supplies build on Applied Kilovolts’ legendary reputation for reliability, being constructed from conservatively rated components with their reliability further enhanced by information gained over many years of field operation.
Available as +ve or -ve up to 50kV, and electrically reversible at voltages up to 30kV.
Please see the HPZ range for zero crossing reversible (bi-polar) units.
We manufacture a large number of customized OEM versions and would be pleased to discuss your application with you.
Electrical Specification Positive & Negative Polarity Units | ||||
---|---|---|---|---|
Unit Type | Polarity | Output | Ripple at Full Load | Size (mm) |
LT001PIP010 | Positive | 10 volts to 1kV at 3mA | 2mV peak to peak | 156x127x64 |
LT001NIP010 | Negative | |||
LT2.5PIP010 | Positive | 10 volts to 2.5kV at 1.2mA | 5mV peak to peak | 156x127x64 |
LT2.5NIP010 | Negative | |||
LT005PIP010 | Positive | 10volts to 5kV at 600uA | 10mV peak to peak | 156x127x64 |
LT005NIP010 | Negative | |||
LT010P IP010 | Positive | 20 volts to 10kV at 300uA | 20mV peak to peak | 156x127x64 |
LT010N IP010 | Negative | |||
LT015P IP010 | Positive | 30 volts to 15kV at 200uA | 30mV peak to peak | 207x148x74 |
LT015N IP010 | Negative | |||
LT020P IP010 | Positive | 50 volts to 20kV at 150uA | 40mV peak to peak | 207x148x74 |
LT020N IP010 | Negative | |||
LT030P IP010 | Positive | 100 volts to 30kV at 100uA | 60mV peak to peak | 207x148x74 |
LT030N IP010 | Negative |
Electrical Specification Reversible Polarity Units | ||||
---|---|---|---|---|
Unit Type | Polarity | Output | Ripple At Full Load | Size (mm) |
LT001RIP010 | REVERSIBLE | ±10V to ±1kV at 3mA | 2mV peak to peak | 163x152x71.5 |
LT2.5RIP010 | REVERSIBLE | ±10V to ±2.5kV at 1.2mA | 5mV peak to peak | 163x152x71.5 |
LT005RIP010 | REVERSIBLE | ±10V to ±5kV at 600uA | 10mV peak to peak | 163x152x71.5 |
LT010RIP010 | REVERSIBLE | ±20V to ±10kV at 300uA | 20mV peak to peak | 163x152x71.5 |
LT015RIP010 | REVERSIBLE | ±30V to ±15kV at 200uA | 30mV peak to peak | 233x204x114 |
LT020RIP010 | REVERSIBLE | ±50V to ±20kV at 150uA | 40mV peak to peak | 233x204x114 |
LT030RIP010 | REVERSIBLE | ±100V to ±30kV at 100uA | 60mV peak to peak | 233x204x114 |
Input Voltage | +24 volt d.c. ±10% at <500mA, for Unipolar, and at <600mA for Reversibles. Negative input terminal common to HV earth return.. | ||
---|---|---|---|
Output Voltage | See tables above. | ||
Line Regulation | Less than 4 ppm of maximum voltage for input changes of 1 volt. | ||
Load Regulation | Less than 10ppm for load changes from 10% to 100%. (Measured at maximum voltage). |
||
Overload Protection | Flashover and short circuit proof. Re-entrant current limit. | ||
Temperature Coefficient | <10ppm/ oC from 20oC to 50 oC | ||
Drift |
|
||
Control | 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%, -1/2%). Input impedance > 100Kohm. EXTERNAL potentiometer = Option Code PP INTERNAL potentiometer = Option Code FP |
||
Readout | Voltage monitor: 0 to +10V represents zero to maximum output, tolerance ±2% (Zout=10k). Precision Current Monitor: 0 to 10V represents zero to 100% o/p current, ±2%, Offset ±0.1% of FS (Zout=10k) |
||
Operating Temperature | 0°C to +50°C | ||
Storage Temperature | -35°C to +85°C | ||
R.F.I. | Steel case for low radiated magnetic field. |
Mechanical Specification | |
---|---|
Fixings | Blind Fasteners into the base. |
Output | By 1 meter screened cable, or optional integrated high voltage connector N.B. Reducing the cable length may increase the ripple voltage. |
Input Connector | 15 way D-type |
e.g. Order Code: LT010NIP010 = negative 10kV unit, LT005PPP010 = positive 5kV unit for control by External Potentiometer. |